1 to 2 of  2 products for 12 volt dc low voltage

Result for "12 volt dc low voltage"
Automatic Gate Opener for Dual Swing Gates, Model FM502

The Mighty Mule DUAL Gate Opener is a heavy-duty, swing gate opener that is very easy to install. Ideal for gates weighing up to 850 lbs. or up to 18ft. long. This 12 Volt, DC-powered low-voltage system is powerful, dependable and durable. Includes...

more >>
Northern Tool
$719.99 See It
Mighty Mule FM352 Opener Kit for Dual Swing Gates - up to 16 feet or 550 lbs - per leaf

Low Voltage Swing Gate Operators designed specifically for rural farm and ranch style applications. The Mighty Mule 352 gate operator system is designed for medium weight double gates. Unlike most Mighty Mule operators, the Mighty Mule 352 uses a 12V automobile or marine battery (not supplied). It also has no control box, the control board is mounted in the operator housing. This versatile Mighty Mule gate operator system is ideal for medium weight tubular steel, vinyl, wood, or chain link double gates. Can be powered by either a low voltage transformer or solar charger.   Features: Designed for gates up to 16 ft (4.9m) long or 550 lbs (249.5kg) each leaf AC or Solar powered to meet the needs of 100% of the market Designed for optimum solar performance with 5 Watt solar panel Works with an automotive or marine battery (not included) which optimizes performance in cold weather FM352 Mighty Mule Kit Includes: One master opener for dual gate One slave opener for dual gate One entry transmitter Installation hardware 10 ft. battery harness Receiver Installation manual (English & Spanish) Plug-in transformer Installation video 2 Warning signs The Mighty Mule 352 E-Z Gate Opener is designed for installation on a pull-to-open dual gate leafs (gates that open into the property). By purchasing an accessory bracket (FM148), the Mighty Mule® 352 E-Z Gate Opener can accommodate a push-to-open dual gate leafs (gates that open out from the property). The gates must not exceed 8 feet and 550 pounds or exceed 16 feet and 150 pounds (please see Technical Specifications on page 10). The Mighty Mule 352 EZ Gate Opener can be used on vinyl, aluminum, chain link, farm tube, and wrought iron gates. The Mighty Mule 352 E-Z Gate Opener accommodates extra transmitters, digital keypads, solar panels, push buttons, automatic gate locks, and other access control products. These optional accessories (see the enclosed Mighty Mule Accessory Catalog) are available at most stores. Your store should be able to special order any accessory not in stock. The Mighty Mule 352 E-Z Gate Opener features adjustable obstruction sensing. This safety feature makes the gate stop and reverse direction within 2 seconds when it comes in contact with an obstruction. MIN is the factory setting; meaning the gate will exert the minimum force on an obstruction before it stops and reverses direction. The Mighty Mule 352 E-Z Gate Opener also has an adjustable auto-close feature. After the gate reaches the fully open position, it can be set to remain open up to 120 seconds before automatically closing. Pressing the transmitter button at any time after the gate opens fully will cause it to closeimmediately. OFF is the factory setting; meaning the gate will stay open until you press the transmitter (or keypad, etc.) again. Technical Specifications: Drive Low friction screw drive (linear actuator) rated for -5º F (-28º C) to +160ºF (+71ºC) Powered by reliable 12 volt DC motor with integral case harde

more >>
Gate Openers Unlimited
$495.00 See It
Additional items that match your search
DSP-22-1 Single Channel Detector for the DoorKing Operator Vehicle Loop Detector

OPERATION A plug-in Two Channel Vehicle detector which will operate on 18 Volts DC nominal. The Diablo DSP-22S detector will add a new dimension of simplicity to your plug-in detector requirements.   This series of Diablo detectors are covered by United States patent number US 7,132,959 “Non-Interfering Vehicle Detection”.  These detectors are virtually crosstalk free in most applications. FEATURES Loop Size - Works on any in-ground inductive loop from 20 to 1500 microhenrys. Indicators - Separate Power/Fail and Detect LED’s for both channels. Detect Memory - Power interruptions of short duration are ignored. If power fails for approximately 1 . seconds or less the detector “remembers” a vehicle. Sensitivity and Reset Push Button - The Reset/Sens. button is used for two  functions. A short press and release of the button will reset the detector and the LED’s will both flash from 1 to 4 times, indicating the detector’s sensitivity level. The detector is shipped from the factory with the sensitivity set at level 3. If a different sensitivity level is required: Push and continue to hold the button until the LED’s start flashing - release the button immediately after the desired number of flashes.   For example, if the sensitivity is to be changed to level 2, push and hold the button until the LED’s flash twice then immediately release the button. The sensitivity level can always be verified by a quick tap on the pushbutton. This will reset the detector and flash the two LED’s indicating the present level. Level 1 - Very Low Level 2 - Low Level 3 - Normal (Factory setting) Level 4 - High   Loop Failure - The green power indicators flashes slowly if the loop circuit is open and quickly if the loop circuit is shorted. This detector will output a “Detect” for either of these loop failed conditions.   Outputs - Solid-state (open transistor collector) for Channel 1 Detect. And a SPDT - 1 Amp relay output for Channel 2.   Size - Height: 4.4” Width: 3.0” Depth: 0.8”   Connector -3 position Male for mating with the gate operator. 7-Pin Connector for external connections. 1 - Loop input for Detector #1 2 - Loop input for Detector #1 3 - Loop input for Detector #2 4 - Loop input for Detector #2 5 - Channel 2 Relay N.O. 6 - Channel 2 Relay COM 7 - Channel 2 Relay NC.   Operating Temperature - -35°F to 165°F (-37°C to 74°C)   Ordering Information: Diablo DSP-22-1 Single Channel unit Diablo DSP-22-2 Two Channel unit

more >>
Gate Openers Unlimited
$107.25 See It
DSP-22-2 Two Channel Detector for the DoorKing Operator Vehicle Loop Detector

OPERATION A plug-in Two Channel Vehicle detector which will operate on 18 Volts DC nominal. The Diablo  DSP-22S detector will add a new dimension of simplicity to your plug-in detector requirements.   This series of Diablo detectors are covered by United States patent number US 7,132,959 “Non-Interfering Vehicle Detection”.  These detectors are virtually crosstalk free in most applications. FEATURES Loop Size - Works on any in-ground inductive loop from 20 to 1500 microhenrys. Indicators - Separate Power/Fail and Detect LED’s for both channels. Detect Memory - Power interruptions of short duration are ignored. If power fails for approximately 1 . seconds or less the detector “remembers” a vehicle. Sensitivity and Reset Push Button - The Reset/Sens. button is used for two  functions. A short press and release of the button will reset the detector and the LED’s will both flash from 1 to 4 times, indicating the detector’s sensitivity level. The detector is shipped from the factory with the sensitivity set at level 3. If a different sensitivity level is required: Push and continue to hold the button until the LED’s start flashing - release the button immediately after the desired number of flashes.   For example, if the sensitivity is to be changed to level 2, push and hold the button until the LED’s flash twice then immediately release the button. The sensitivity level can always be verified by a quick tap on the pushbutton. This will reset the detector and flash the two LED’s indicating the present level. Level 1 - Very Low Level 2 - Low Level 3 - Normal (Factory setting) Level 4 - High   Loop Failure - The green power indicators flashes slowly if the loop circuit is open and quickly if the loop circuit is shorted. This detector will output a “Detect” for either of these loop failed conditions.   Outputs - Solid-state (open transistor collector) for Channel 1 Detect. And a SPDT - 1 Amp relay output for Channel 2.   Size - Height: 4.4” Width: 3.0” Depth: 0.8”   Connector -3 position Male for mating with the gate operator. 7-Pin Connector for external connections. 1 - Loop input for Detector #1 2 - Loop input for Detector #1 3 - Loop input for Detector #2 4 - Loop input for Detector #2 5 - Channel 2 Relay N.O. 6 - Channel 2 Relay COM 7 - Channel 2 Relay NC.   Operating Temperature - -35°F to 165°F (-37°C to 74°C)   Ordering Information: Diablo DSP-22-1 Single Channel unit Diablo DSP-22-2 Two Channel unit

more >>
Gate Openers Unlimited
$197.60 See It
Door Bell Accessories: Heath Zenith Door Bell & Chimes 12 Volt DC Replacement Battery For Wireless Push Buttons SL-6198-B

The SL-6198 is a 12 volt DC alkaline battery used in Heath/Zenith wireless push buttons.

more >>
HomeDepot.com
$3.64 See It
SW2000XL Swing Gate Opener

The GTO SW2000XL will operate a gate up to 16' long or weighing 500 lbs. (182 kg) each leaf; if all proper installation procedures have been followed. Ball bearing hinges should be used on all gates weighing over 250 lbs (113.4 kg). Includes battery backup, radio receiver, entry transmitter, AC transformer, and all necessary mounting hardware for a post mounted installation, 10” (25.4 cm) total offset.   FEATURES• Features GTO SW2000XL true soft start and stop operation. Open and close times from 15 seconds.• Full systems capable, single/dual control board includes an adjustable obstruction sensing, gate sequencing and auto close settings.• U.L. rated for Class I, II, III & IV. System certified to be in compliance with U.L. 325, 5th edition. CONTROLS• The GTO SW2000XL control board can be programmed for pull-to-open or push-to-open.• Adjustable auto close, obstruction sensitivity and dual gate sequencing.• One button auto-memorization of digital transmitter code.• Charging regulated circuit on control board. “Sleep draw” is 20 mA; “active draw” is 2 to 7 amps.• GTO / PRO remote-mounted 318 MHz RF receiver and one button transmitter included. POWERThe GTO PRO SW2000XL system is powered by one 12 Volt DC / 7.0 amp hour, sealed, rechargeable battery (included). Batterycharge is maintained by a120V AC/60 Htz input and 18V AC at 40 VA. output transformer, rectified to 14V DC through control board. OPTIONS:Solar Panel Charger: float voltage 14.5 V DC output from a 19-3/8” (49.21 cm) x 15 1/4” (38.74 cm) silicon alloy panel.Generates minimum of 10 watts at 600 mA. A gated diode on the control board prevents battery discharge. (FM123) SUGGESTED ACCESSORIES:• Automatic Gate Lock (FM144/FM142)• Residential Intercom / Keypad (F3100MBC)• Gooseneck Pedestal (F100 / F110)• Driveway Exit Wand (FM139, FM140, FM141)• Solar Panel (FM122 / FM123)• Keychain Transmitter (RB741 / RB742 / RB743)• Digital Keypad (F310)

more >>
Gate Openers Unlimited
$529.00 See It
SW4000XLS Swing Gate Opener

XLS IMPROVEMENTS• Increased operating speed by 10%• NEW rev-counter board with reed switch technology (backward compatible)• Reinstated larger control box• Reinstated heavy duty hardware for 1000 lb. - 20 ft. gates• IMPROVED front mount and scraper seal designIncludes battery backup, radio receiver, entry transmitter, AC transformer and all necessary mounting hardware for a post mounted installation, 17˝ (43.2 cm) total offset.The PRO SW4000XLS series will operate a gate up to 20 ft. (6.1 m) long and weighing 1000 lbs. (453 kg) each leaf if all proper installation procedures have been followed. Ball bearing hinges should be used on all gates weighing over 250 lbs. (113.4 kg).FEATURES:▶ One button auto-memorization of digital transmitter code.▶Includes battery backup, 318 MHz RF radio receiver, entry transmitter, AC transformer and all necessary mounting hardware for a post mounted installation, 17˝ (43 cm) total offset.MECHANICAL:• The GTO/PRO® control board can be programmed for pull-to-open or push-to-open.• Operating temp -5 F (-21C) to +160 F (71 C).• Opening time: from 18 to 20 seconds (typical installation).• Range of arm stroke: is up to 22˝ (56 cm).• Operator length: with arm fully retracted is 46.25˝ (118 cm), mounting point to mounting point.• Operation, diagnostic and safety alarms,• Inherent obstruction sensing.• Soft start/soft stop—for long mechanical life expectancy.• Auto close adjustable 3–120 seconds delay.ELECTRICAL/POWER:• 12 Volt DC / 7.0 amp hour, sealed, rechargeable battery (included).Battery charge is maintained by a 120V AC/60 Hz input, 18V AC, 40 VA output, transformer through control board.• Powered by a reliable 12 Volt (120 Watt) DC motor, 16:1 planetary gear drive system.• Charging regulated circuit on control board. “Sleep draw” is 15 mA; “active draw” is 3 to 7 amps.WARRANTY:2 Year (RESIDENTIAL application)CLASS OF OPERATION:Class ISAFETY LISTINGS:System Certified with UL325 5th Edition safety standards, ETL listed.OPTIONS:Solar Power: For dual gates, we recommend a minimum of 10 watts. (FM123)Dual Gates: The PRO-SW4200XLS works as a second gate operator when combined with a PRO-SW4000XLS. Includes 50 ft. (15.2m) power cable.Push to Open applications: require one Push-to-Open bracket per operator (R4KPTO per operator).SUGGESTED ACCESSORIES:• Automatic Gate Lock (FM144/FM142)• Residential Intercom / Keypad (F3100MBC)• Gooseneck Pedestal (F100 / F110)• Driveway Exit Wand (FM139, FM140, FM141)• Solar Panel (FM122 / FM123)• Keychain Transmitter (RB741 / RB742 / RB743)• Digital Keypad (F310)

more >>
Gate Openers Unlimited
$955.00 See It
DSP- 50 Plug-in Vehicle Loop Detector

FEATURES The Diablo DSP-51AT detector can be configured to provide an output for tailgating vehicles or as an accurate vehicle counter. The detector has enhanced Anti-Tailgating features that allow the end user to select the allowed number of vehicles through a secured access. The enhancements are not only for tailgating but also for providing an accurate vehicle count output as a secondary feature. The Diablo DSP-51AT was designed for use with current typical loop configurations and sizes used throughout the industry. The simplicity of the set-up and operation allows the end user to implement the detector without special training devices.   OPERATION The Diablo DSP-51AT is mainly a standard vehicle loop detector. But that’s where the similarity ends. Its built-in secondary functions are exclusive anti-tailgating and vehicle counting software. The two modes are selectable from a front panel DIP switch. In the anti-tailgate mode, the software compares the signature versus the number of legal vehicles input. If there is any discrepancy, the secondary output is enabled indicating a tailgating incident. In the counting mode, the secondary output is pulsed once for every vehicle entering the loop system based on a proprietary signature algorithm.   FRONT PANEL SELECTABLE SWITCHES SENSITIVITY SWITCH This detector has a 10 position rotary sensitivity switch. The unit is shipped in the “5” position which is the normal sensitivity level. Sensitivity can be adjusted up and down from this level to accommodate different street loops.   FUNCTION SWITCHES The detector has a 6-position DIP switch to incorporate the following functions. DIPSWITCHES 5 and 6 – Frequency One of four operating frequencies can be selected by changing these two switches. DIPSWITCH 4 – Failure Operation OFF = Fail Safe operation. ON = Fail Secure operation. DIPSWITCH 3 – Failure Output Polarity OFF = Fail output low indicates loop failure ON = Fail output high indicates loop failure DIPSWITCH 2 – Operating Mode OFF = Anti-Tailgating Operation ON = Counter Operation DIPSWITCH 1 – Anti-Tailgating Test Toggle switch to indicate number of vehicles in inbound queue.   INDICATORS   Green LED solid ON is power OK. Fast blink = “Shorted” loop. Slow blink = “Open” loop circuit.   Red LED's OFF = No Detect. ON = Detect   Blue LED On = Output B On   Yellow LED OFF = Unarmed. ON = AT armed   Outputs - Three separate solid state (normally open collector) outputs – 30 milliamps maximum and 20volts maximum. Output pins – (looking into the connector – Right to left.) 1 Loop 2 Loop 3 Power input “+” 4 N/C 5 /AT input 6 Output B 7 Fail 8 Output A 9 Power input “+” 10 Power (and logic) Common Operating Temperature - -35°F to 165°F (-37°C to 74°C)   Power - 10 to 30 Volts D.C. ( 30 mA. max at 12 volts)   Enclosure - Impact resistant, high temperature plastic. H - 2.375” (60.4 mm) W – 0.86” (22 mm) D -2.25 ” (58mm)

more >>
Gate Openers Unlimited
$108.25 See It
DSP-7 Microdetector Vehicle Loop Detector

OPERATION The Diablo DSP-7LP vehicle detector has been specifically designed for solar powered gate applications specifically for “fail safe” operations, such as on safety loops. This detector will operate on any voltage from 10 to 30 Volts AC or DC and draws approximately 1 milliampere while waiting for a car. Thepower LED winks continuously once per second to indicate the detector is operating in the low power mode. The Diablo DSP-7LP detector has many of the same features as our standard Diablo DSP-7 but beats all competition for reliability, simplicity, and “no car”current consumption. This series of Diablo’s detectors are covered by United States patent number US 7,132,959“Non-Interfering Vehicle Detection". These detectors are virtually crosstalk free in most applications. Working on battery-powered and other parking and access control loop applications, the Diablo DSP-7LP is preset to the normal sensitivity level used in parking/access control applications, and tunes itself to the best operating frequency. This micro-sized detector will automatically adjust its sensitivity level when used on different sized loops. Environmental conditions are constantly compensated with the Diablo DSP-7LP’s HYPERTRACK software.FEATURESLoop Size - Works on any in-ground inductive loop from 20 to 1200 μH.Indicators - Separate Power and Detect LED’s. The green Power LED will wink continuously once per second under normal operation. The red Detect LED will turn on solid for a vehicle.Sensitivity - Automatic - compensates for large loops and large lead-ins.Output Ratings - Single output, 1 amp relay at 30 VDCResistive - The relay common, NO, and NC contacts are available.Loop Failure - The green power indicator flashes twice per second if the loop circuit is open and 10 times per second if the loop circuit is shorted. This detector operates in the fail safe mode and will output a “Detect”for either of these loop failure conditions. This “Fail safe” detector should be used on “safety” loops. Power - 10 to 30 Volts AC or DC. Approximately 1 mA (no car and all loop sizes) and less than 25 mA with a car on the loop or while in a “Fail”conditionSize - Height: 1.52” Width: 2.9” Depth: 1.56”Connector - Removable 7-pin terminal block. Pin assignments are shown below - from left to right:1 - Relay (NC) (opens for detect)2 - Relay Common3 - Relay (NO) (closes for detect)4 - Power Common5 - Power in (10 to 30 Volts AC or +DC)6 - Loop7 - Loop Operating Temperature - -35°F to 165°F (-37°C to 74°C)

more >>
Gate Openers Unlimited
$108.95 See It
Door Bell Accessories: IQ America Door Bell & Chimes 16-Volt/10-Watt Wired Doorbell Transformer DT-1610A

This Wired Door Chime Transformer has a Low-Voltage wired design and its output is 16-Volt/10-Watt. It has a lock-nut design for easy attachment to an outlet box.

more >>
HomeDepot.com
$8.22 See It
DSP-11-117 Microdetector Vehicle Loop Detector

OPERATION   The Diablo DSP-11 Vehicle is a simple, switchless vehicle detector available with the industry standard 11-pin base. Two models for your complete 11-pin vehicle detector needs: ・ The Diablo DSP-11-LV which will operate on any voltage ・ and any polarity from 10 to 30 Volts AC or DC. ・ The DSP-11-117 operates on 117 VAC lines.     This series of Diablo’s detectors are covered by United States patent number US 7,132,959 “Non-Interfering Vehicle Detection”. These detectors are virtually crosstalk free in most applications and have been specifically designed to handle parking, drive-through and access control applications.   FEATURES Loop Size - Works on any in-ground inductive loop from 20 to over 1500 mH. Indicators - Separate Power/Fail and Detect LEDs. Detect Memory - Power interruptions of short duration are ignored. If power fails for approximately 1. seconds or less the detector “remembers” a vehicle. Sensitivity - Automatic - compensates for large loops and long lead-ins. Output Relay - 1A at 125VAC General use, 1A at 30 VDC resistive. Both N.O. (closes for detect) and N.C. (opens for detect) outputs. Loop Failure - The green power indicator flashes slowly if the loop circuit is open and quickly if the loop circuit is shorted. This detector will output a “Detect” for either of these loop failed conditions. Model Types Diablo DSP-11-LV - Low voltage version 10 to 30 Volts AC or DC Diablo DSP-11-117 - Medium voltage version for 117 Volts AC Fail Safe Operation - The DSP-11 series of detectors are designed to be “Fail Safe” in their operation.  The detector will output a “Detect” (contact closure) for a “Failed”loop condition OR a loss of power  to the detector. This “Fail Safe” detector should always be used on “safety” loops. Connector - Standard 11-pin (Amphenol 86CP11) Pin assignments are: Pin 1 (black wire) - Power in (See model type) Pin 2 (white wire) - Power in (See model type) Pin 5 (yellow wire) - Output relay common Pin 6 (blue wire) - Output relay N.O. - (closes for detect) Pin 7 (gray twisted wire) - Loop input Pin 8 (brown twisted wire) - Loop input Pin 10 (pink wire*) - Output relay N.C. - (opens for detect) *This wire is black (with white) on some harnesses. Operating Temperature - -35°F to 165°F (-37°C to 74°C) Size - Height: 1.4” Width: 1.4” Depth: 2.75” overall

more >>
Gate Openers Unlimited
$102.00 See It
DSP-11-LV Microdetector Vehicle Loop Detector

OPERATION   The Diablo DSP-11 Vehicle is a simple, switchless vehicle detector available with the industry standard 11-pin base. Two models for your complete 11-pin vehicle detector needs: ・ The Diablo DSP-11-LV which will operate on any voltage ・ and any polarity from 10 to 30 Volts AC or DC. ・ The Diablo DSP-11-117 operates on 117 VAC lines.     This series of Diablo’s detectors are covered by United States patent number US 7,132,959 “Non-Interfering Vehicle Detection”. These detectors are virtually crosstalk free in most applications and have been specifically designed to handle parking, drive-through and access control applications.   FEATURES Loop Size - Works on any in-ground inductive loop from 20 to over 1500 mH. Indicators - Separate Power/Fail and Detect LEDs. Detect Memory - Power interruptions of short duration are ignored. If power fails for approximately 1. seconds or less the detector “remembers” a vehicle. Sensitivity - Automatic - compensates for large loops and long lead-ins. Output Relay - 1A at 125VAC General use, 1A at 30 VDC resistive. Both N.O. (closes for detect) and N.C. (opens for detect) outputs. Loop Failure - The green power indicator flashes slowly if the loop circuit is open and quickly if the loop circuit is shorted. This detector will output a “Detect” for either of these loop failed conditions. Model Types DSP-11-LV - Low voltage version 10 to 30 Volts AC or DC DSP-11-117 - Medium voltage version for 117 Volts AC Fail Safe Operation - The DSP-11 series of detectors are designed to be “Fail Safe” in their operation.  The detector will output a “Detect” (contact closure) for a “Failed”loop condition OR a loss of power  to the detector. This “Fail Safe” detector should always be used on “safety” loops. Connector - Standard 11-pin (Amphenol 86CP11) Pin assignments are: Pin 1 (black wire) - Power in (See model type) Pin 2 (white wire) - Power in (See model type) Pin 5 (yellow wire) - Output relay common Pin 6 (blue wire) - Output relay N.O. - (closes for detect) Pin 7 (gray twisted wire) - Loop input Pin 8 (brown twisted wire) - Loop input Pin 10 (pink wire*) - Output relay N.C. - (opens for detect) *This wire is black (with white) on some harnesses. Operating Temperature - -35°F to 165°F (-37°C to 74°C) Size - Height: 1.4” Width: 1.4” Depth: 2.75” overall

more >>
Gate Openers Unlimited
$102.00 See It
DSP-6LP Microdetector Vehicle Loop Detector

OPERATION   The Diablo DSP-6LP vehicle detector is designed for solar powered gate applications. This loop detector will operate on any voltage from 10 to 30 Volts AC or DC and draws approximately 1 milliampere while waiting for a car. The power LED winks continuously once per second to indicate the detector is operating in the low power mode.   The Diablo DSP-6LP detector beats all competition for reliability, simplicity, and “no car” current consumption. This series of Diablo Loop detectors are covered by United States patent number US 7,132,959 “Non-Interfering Vehicle Detection”. These detectors are virtually crosstalk free in most applications.   Working on battery-powered and other parking and access control loop applications, the Diablo DSP-6LP is preset to the normal sensitivity level used in parking/access control applications, and tunes itself to the best operating frequency.   This micro-sized detector will automatically adjust its sensitivity level when used on different sized loops. Environmental conditions are constantly compensated with the Diablo Control DSP-6LP  HYPERTRACK software. Environmental conditions are constantly compensated with the DML-9LP’s HYPERTRACK software. FEATURES Loop Size - Works on any in-ground inductive loop from 20 to 1200 mH. Indicators - Separate Power and Detect LED’s. The green Power LED will wink continuously once per second under normal operation. The red Detect LED will turn on solid for a vehicle. Sensitivity - Automatic - compensates for large loops and large lead-ins. Output Ratings - Single output, 1 amp relay at 30 VDC Resistive - The relay common, NO, and NC contacts are available. Ordering Information – DSP-6LP standard version. Power - 10 to 30 Volts AC or DC. Approximately 1 mA (no car and all loop sizes) and less than 25 mA with a car on the loop. Size - Height: 1.52” Width: 2.9” Depth: 1.56”   Connector - Removable 7-pin terminal block. Pin assignments are shown below -from left to right: 1 - Relay (NC) (opens for detect) 2 - Relay Common 3 - Relay (NO) (closes for detect) 4 - Power Common 5 - Power in (10 to 30 Volts AC or +DC) 6 - Loop 7 - Loop   Operating Temperature -35°F to 165°F (-37°C to 74°C)

more >>
Gate Openers Unlimited
$108.95 See It
DML- 9LP Probe Kit Vehicle Loop Detector

OPERATION The Diablo DML-9LP vehicle sensor kit is designed for solar powered gate applications. This detector will operate on any voltage from 10 to 30 volts AC or DC and draws approximately 3 milliampere while waiting for a vehicle. The power LED winks continuously once per second to indicate the detector is operating in the low power mode. The Diablo DML-9LP probe beats all competition for reliability, simplicity and “no car” current consumption.   This series of Diablo loop detectors are covered by United States patent number US 7,132,959 “Non-Interfering Vehicle Detection”. These detectors are virtually crosstalk free in most applications.   Working on battery-powered and other parking and access control loop applications, the Diablo DML-9LP is preset to the normal sensitivity level used in parking/access control applications and tunes itself to the best operating frequency. Environmental conditions are constantly compensated with the Diablo DML-9LP’s HYPERTRACK software. FEATURES Indicators - Separate Power and Detect  LED’s. The GREEN Power LED will wink continuously once per second under normal operation. The RED Detect LED will turn on solid for a vehicle. Sensitivity - Automatic - compensates for extra long lead-ins. Probe Failure - The GREEN power indicator flashes twice per second if the probe circuit is open and 10 times per second if the probe circuit is shorted. This detector operates in the fall secure mode and will not output a “Detect” for either of these probe failure conditions. This “Fail secure” detector should be used on “free exit” loops. Operating Temperature - -35°F to 165°F (-37°C to 74°C) Power - 10 to 30 Volts D.C. Approximately 3mA (no car on probe) and less than 25mA with car on the probe. Size - Height 1.52” Width 2.9” Depth 1.56” Connector - Removable 7-pin terminal block. Pin assignments are shown at  right below.

more >>
Gate Openers Unlimited
$224.75 See It
DSP-7LP Microdetector Vehicle Loop Detector

OPERATION   The Diablo DSP-7LP vehicle detector has been specifically designed for solar powered gate applications specifically for “fail safe” operations, such as on safety loops. This loop detector will operate on any voltage from 10 to 30 Volts AC or DC and draws approximately 1 milliampere while waiting for a car. The power LED winks continuously once per second to indicate the detector is operating in the low power mode. The Diablo DSP-7LP detector has many of the same features as our standard Diablo DSP-7 but beats all competition for reliability, simplicity, and “no car”current consumption.   This series of Diablo’s detectors are covered by United States patent number US 7,132,959 “Non-Interfering Vehicle Detection". These detectors are virtually crosstalk free in most applications.   Working on battery-powered and other parking and access control loop applications, the Diablo Controls DSP-7LP is preset to the normal sensitivity level used in parking/access control applications, and tunes itself to the best operating frequency.   This micro-sized detector will automatically adjust its sensitivity level when used on different sized loops. Environmental conditions are constantly compensated with the Diablo DSP-7LP HYPERTRACK software. FEATURES Loop Size - Works on any in-ground inductive loop from 20 to 1200 μH. Indicators - Separate Power and Detect LED’s. The green Power LED will wink continuously once per second under normal operation. The red Detect LED will turn on solid for a vehicle. Sensitivity - Automatic - compensates for large loops and large lead-ins. Output Ratings - Single output, 1 amp relay at 30 VDC Resistive - The relay common, NO, and NC contacts are available. Loop Failure - The green power indicator flashes twice per second if the loop circuit is open and 10 times per second if the loop circuit is shorted. This detector operates in the fail safe mode and will output a “Detect” for either of these loop failure conditions. This “Fail safe” detector should be used on “safety” loops. Power - 10 to 30 Volts AC or DC. Approximately 1 mA (no car and all loop sizes) and less than 25 mA with a car on the loop or while in a “Fail” condition Size - Height: 1.52” Width: 2.9” Depth: 1.56” Connector - Removable 7-pin terminal block. Pin assignments are shown below - from left to right: 1 - Relay (NC) (opens for detect) 2 - Relay Common 3 - Relay (NO) (closes for detect) 4 - Power Common 5 - Power in (10 to 30 Volts AC or +DC) 6 - Loop 7 - Loop   Operating Temperature - -35°F to 165°F (-37°C to 74°C)

more >>
Gate Openers Unlimited
$108.95 See It
Door Bell Accessories: IQ America Door Bell & Chimes Multi-Voltage Wired Doorbell Transformer DT-1624A

This Multiple-Voltage Wired Door Chime Transformer can be used when replacing a door bell with a door chime. It has a Low-Voltage wired design and 3 selectable outputs.

more >>
HomeDepot.com
$12.97 See It
Mighty Mule FM200 Opener Kit for single Swing Gates - up to 12 feet or 300 lbs.

Mighty Mule Single Swing Gate Opener Kit For a Single Swing Gate Up To 12 Ft. or 300 Lbs. The Mighty Mule FM200 Single Opener can be used in residential applications including automating gates made of farm tubing, steel, aluminum, wood, and chain link, along with many other gate types. This opener can be set on the left or right and is used in the standard pull-to-open operation.   Features: Designed for gates up to 12 ft (3.7m) long or 300 lbs (136.1kg) AC or Solar powered to meet the needs of 100% of the market Designed for optimum solar performance with 5 Watt solar panel Works with an automotive or marine battery (not included) which optimizes performance in cold weather FM200 Mighty Mule Kit Includes: One FM200 opener for single gate One entry transmitter Installation hardware 10 ft. batery harness Receiver Installation manual (English & Spanish) Plug-in transformer 2 Warning signs The Mighty Mule FM200 Single Gate Opener can be used in residential applications including automating gates made of farm tubing, steel, aluminum, wood, and chain link, along with many other gate types. This opener can be set on the left or right and is used in the standard pull-to-open operation. The Mighty Mule FM200 Single Gate Opener is a low voltage system, eliminating the need to run 110 AC to your gate. Simply run 16-gauge low voltage to a household outlet within 1000’ of the operator or use a solar panel. The Mighty Mule FM200 runs off of a deep cycle marine battery (battery and housing for battery not included). The large battery allows for a large storage capacity of cycles (Provides up to 1,500 back-up cycles with fully charged battery). This unit also has a small control box, easy to mount in many locations. The Mighty Mule FM200 Single Gate Opener can be used with GTO Inc.’s complete line of accessories including keypads, transmitters, exit wands, gate locks, solar panels, and more. Closing Timer – Set your gate to close between 0 and 120 seconds after reaching the full open position or turn this option off to leave it open until an entry device activates closing motion. Learn Mode – With the Mighty Mule FM200 the learning process, the end points are determined by the user via remote. A simple press of the transmitter tells the opener where to stop and when the opener is set to the desired stop points, save the settings on the board. Economical Price – The Mighty Mule FM250 is the most cost effective gate oepner on the market today

more >>
Gate Openers Unlimited
$213.00 See It
DSP-15 Parking/Access Control Detector Vehicle Loop Detector

Diablo DSP-15 Vehicle Detector A single unit for all low voltages – 10 to 30 Volts AC or DC OPERATION The Diablo DSP-15 vehicle detector has been specifically designed to handle all parking, drive-through and access control applications.             Working on virtually any size loop, the Diablo DSP-15 automatically tunes itself to the best operating frequency within the selected range. Environmental conditions are constantly compensated with the Diablo DSP-15 HYPERTRACK software. The DSP-15’s inherent noise filtering algorithms allow it to work reliably in any electrical situation.             It can be used as either a safety loop or free exit loop detector. With the flexibility to be either “fail safe” or “fail secure,” it is the only parking detector you will ever need.   FEATURES Loop Size - Works on any in-ground inductive loop from 20 to 1000 mH. Fail Safe or Fail Secure Operation - Can be easily changed to either mode in the field. Indicators - Separate Power/Fail and Detect LEDs. Connector - Ten position terminal block or 10 pin male Molex connector Sensitivity - Ten sensitivity settings. Frequency - Automatically tunes within one of four operating ranges. Outputs - Two separate relay outputs with features that are switch programmable as follows: Output A - Main detection output which can be modified by delay and extension. Fail safe or fail secure operation changeable by PCB jumper. NOTE: Units are shipped in the Fail Safe mode. Output B – Switch selectable to one of the following four options: 1) True presence (no extension or delay) 2) Pulse on vehicle entering loop 3) Pulse on vehicle exiting loop 4) Loop Fail output Sensitivity Boost - Can be used in special applications to insure complete detection of high-bed vehicles. Hold Time - Normal or extended hold time is selectable. Loop Failure - If the loop fails, opens or shorts, the power indicator flashes. Output B can also indicate this condition if desired (see above). The option to “remember” an intermittent loop failure is also provided. Delay - Can be selected to ignore fast moving vehicles over the loop. Extension - Extends a call for slow moving vehicles. Sensitivity - Experience has shown that almost all parking and access control applications can be handled with sensitivity set at NORMAL (level 5). The rotary sensitivity switch is rarely moved from NORMAL. However, the DSP- 15 has ten sensitivity settings varying from LOW (level 0) to HIGH (level 9).

more >>
Gate Openers Unlimited
$115.50 See It
Search within results