1 to 20 of  25 products for panasonic tcp60st30

No exact matches found for panasonic tcp60st30

25 similar items found

0700030 - Phoenix Contact-0700030-TCP 30/DC32V

DimensionsLength: 20 mmWidth: 6 mmGeneralColor: light greenInsulating material: PATechnical dataAmbient temperature (operation): -40 °C ... 85 °CFuse: Slow-blowFuse type: Automatic deviceNominal current IN: 30 ANominal voltage UN: 32 V AC/DC

more >>
BW Rogers Co
$12.54 See It
0712314 - Phoenix Contact-0712314-TCP 10A

DimensionsHeight NS 35/7.5: 55 mmLength: 24.5 mmWidth: 8.2 mmGeneralColor: blackInflammability class according to UL 94: V0Installation instructions: When mounted in rows, the nominal device current can be limited to just 80% or must be overdimensioned accordingly.Insulating material: PPSTechnical dataFuse: Slow-blowFuse type: Automatic deviceInsulating material group: IIIbNominal current IN: 10 ANominal voltage UN: 250 V ACNominal voltage UN: 65 V DCPollution degree: 2Surge voltage category: II

more >>
BW Rogers Co
$15.67 See It
DX80P9T6W - Banner Engineering DX80 Star 900MHz GatewayPro 150mW IP67; 10-30Vdc Ent Antenn

DX80P9T6W - Banner Engineering DX80 Star 900MHz GatewayPro 150mW IP67; 10-30Vdc Ent Antenna RS485; Modbus/TCP-EtherNet/IP Protocol Conversion

more >>
Walker EMD
$1,195.00 See It
0712291 - Phoenix Contact-0712291-TCP 8A

DimensionsHeight NS 35/7.5: 55 mmLength: 24.5 mmWidth: 8.2 mmGeneralColor: blackInflammability class according to UL 94: V0Installation instructions: When mounted in rows, the nominal device current can be limited to just 80% or must be overdimensioned accordingly.Insulating material: PPSTechnical dataFuse: Slow-blowFuse type: Automatic deviceInsulating material group: IIIbNominal current IN: 8 ANominal voltage UN: 250 V ACNominal voltage UN: 65 V DCPollution degree: 2Surge voltage category: II

more >>
BW Rogers Co
$15.67 See It
0712217 - Phoenix Contact-0712217-TCP 2A

DimensionsHeight NS 35/7.5: 55 mmLength: 24.5 mmWidth: 8.2 mmGeneralColor: blackInflammability class according to UL 94: V0Installation instructions: When mounted in rows, the nominal device current can be limited to just 80% or must be overdimensioned accordingly.Insulating material: PPSTechnical dataFuse: Slow-blowFuse type: Automatic deviceInsulating material group: IIIbNominal current IN: 2 ANominal voltage UN: 250 V ACNominal voltage UN: 65 V DCPollution degree: 2Surge voltage category: II

more >>
BW Rogers Co
$15.67 See It
DX80P9T6S - Banner Engineering DX80 Star 900MHz GatewayPro 150mW IP67; 10-30Vdc Ext Antenn

DX80P9T6S - Banner Engineering DX80 Star 900MHz GatewayPro 150mW IP67; 10-30Vdc Ext Antenna RS485; Modbus/TCP-EtherNet/IP Protocol Conversion

more >>
Walker EMD
$1,195.00 See It
0712233 - Phoenix Contact-0712233-TCP 3A

DimensionsHeight NS 35/7.5: 55 mmLength: 24.5 mmWidth: 8.2 mmGeneralColor: blackInflammability class according to UL 94: V0Installation instructions: When mounted in rows, the nominal device current can be limited to just 80% or must be overdimensioned accordingly.Insulating material: PPSTechnical dataFuse: Slow-blowFuse type: Automatic deviceInsulating material group: IIIbNominal current IN: 3 ANominal voltage UN: 250 V ACNominal voltage UN: 65 V DCPollution degree: 2Surge voltage category: II

more >>
BW Rogers Co
$15.67 See It
0700040 - Phoenix Contact-0700040-TCP 40/DC32V

DimensionsLength: 20 mmWidth: 6 mmGeneralColor: orangeInsulating material: PATechnical dataAmbient temperature (operation): -40 °C ... 85 °CFuse: Slow-blowFuse type: Automatic deviceNominal current IN: 40 ANominal voltage UN: 32 V AC/DC

more >>
BW Rogers Co
$11.49 See It
DX80P2T6S - Banner Engineering DX80 Star 2.4GHz GatewayPro 65mW IP67; 10-30Vdc Ext Antenna

DX80P2T6S - Banner Engineering DX80 Star 2.4GHz GatewayPro 65mW IP67; 10-30Vdc Ext Antenna RS485; Modbus/TCP-EtherNet/IP Protocol Conversion

more >>
Walker EMD
$1,195.00 See It
0700020 - Phoenix Contact-0700020-TCP 20/DC32V

DimensionsLength: 20 mmWidth: 6 mmGeneralColor: yellowInsulating material: PATechnical dataAmbient temperature (operation): -40 °C ... 85 °CFuse: Slow-blowFuse type: Automatic deviceNominal current IN: 20 ANominal voltage UN: 32 V AC/DC

more >>
BW Rogers Co
$12.54 See It
0700005 - Phoenix Contact-0700005-TCP 5/DC32V

DimensionsWidth: 6 mmGeneralColor: light brownInsulating material: PATechnical dataAmbient temperature (operation): -40 °C ... 85 °CFuse: Slow-blowFuse type: Automatic deviceNominal current IN: 5 ANominal voltage UN: 32 V ACNominal voltage UN: 32 V DC

more >>
BW Rogers Co
$12.54 See It
DX80P2T6W - Banner Engineering DX80 Star 2.4GHz GatewayPro 65mW IP67; 10-30Vdc Int Antenna

DX80P2T6W - Banner Engineering DX80 Star 2.4GHz GatewayPro 65mW IP67; 10-30Vdc Int Antenna RS485; Modbus/TCP-EtherNet/IP Protocol Conversion

more >>
Walker EMD
$1,195.00 See It
0700015 - Phoenix Contact-0700015-TCP 15/DC32V

DimensionsLength: 20 mmWidth: 6 mmGeneralColor: blueInsulating material: PATechnical dataAmbient temperature (operation): -40 °C ... 85 °CFuse: Slow-blowFuse type: Automatic deviceNominal current IN: 15 ANominal voltage UN: 32 V AC/DC

more >>
BW Rogers Co
$12.54 See It
0700025 - Phoenix Contact-0700025-TCP 25/DC32V

DimensionsLength: 20 mmWidth: 6 mmGeneralColor: whiteInsulating material: PATechnical dataAmbient temperature (operation): -40 °C ... 85 °CFuse: Slow-blowFuse type: Automatic deviceNominal current IN: 25 ANominal voltage UN: 32 V AC/DC

more >>
BW Rogers Co
$12.54 See It
DX80P9T6S-P - Banner Engineering DX80 Perf 900MHz GatewayPro 1W IP67; 10-30Vdc Ext Antenna

DX80P9T6S-P - Banner Engineering DX80 Perf 900MHz GatewayPro 1W IP67; 10-30Vdc Ext Antenna RS485; Modbus/TCP-EtherNet/IP Protocol Conversion

more >>
Walker EMD
$1,195.00 See It
DX80P2T6S-P - Banner Engineering DX80 Perf 2.4GHz GatewayPro 65mW IP67; 10-30Vdc Ext Anten

DX80P2T6S-P - Banner Engineering DX80 Perf 2.4GHz GatewayPro 65mW IP67; 10-30Vdc Ext Antenna RS485; Modbus/TCP-EtherNet/IP Protocol Conversion

more >>
Walker EMD
$1,195.00 See It
2989226 - Phoenix Contact-2989226-FL SWITCH SMCS 8TX

FunctionBasic functions: Store-and-forward switch complies with IEEE 802.3 2 priority classes as per IEEE 802.1 P TCP/IP protocol, BootP-capable, port-mirroring, integrated web server function, multicast filtering, IGMP snooping, VLAN, Rapid Spanning Tree (RSTP), PROFINET IO Device, media redundancy protocol (MRP).Management: Web based management, SNMP or over V.24 (RS-232)Redundancy: Spanning Tree 802.1d, Rapid Spanning Tree 802.1w, Fast Ring Detection, Media Redundancy Protocol (MRP) as per IEC 62439Status and diagnostic indicators: Per Ethernet 2 status LEDs: LINK and status activity with switch-over, 100, full duplex, supply voltage Us1 and Us2 (redundant supply voltage) and FAILSupported browsers: Internet Explorer 5.5 or higherGeneral dataAir pressure (operation): 86 kPa ... 108 kPa (2000 m above sea level)Air pressure (storage/transport): 66 kPa ... 108 kPa (3500 m above sea level)Ambient temperature (operation): 0 °C ... 55 °CAmbient temperature (storage/transport): -40 °C ... 85 °CDegree of protection: IP20Depth: 69 mmHeight: 100 mmMounting type: DIN railNoise emission: EN 61000-6-3:2001+A11Permissible humidity (operation): 5 % ... 95 % (no condensation)Permissible humidity (storage/transport): 5 % ... 95 % (no condensation)Type AX: Block-orientedWeight: 650 gWidth: 128 mmInterfacesConnection method: RJ45Connection method: V.24 (RS-232-C), 6-pos. MINI-DIN female connector (PS/2)Interface 1: Ethernet (RJ45)Interface 5: Serial (V.24 (RS-232))No. of ports: 8 (RJ45 ports)Note on connection method: Auto negotiation and autocrossingSignal LEDs: Supply voltage, data transmission, error, link, activityTransmission length: 100 m (per segment)Transmission physics: CopperTransmission speed: 10/100 MBit/sNetwork expansion parametersCascading depth: Network, linear, and star structure: anyMaximum conductor length ((twisted pair): 100 mSupply voltageResidual ripple: 3.6 VPP (within the permitted voltage range)Supply voltage: 24 V DCSupply voltage range: 18 V DC ... 32 V DCTypical current consumption: 600 mA (at US = 24 V DC)

more >>
BW Rogers Co
$851.58 See It
SC22-3E-S - Banner Engineering Safety Controller with Screw Terminals, XM Card

New to the Safety Controller family is the SC22-3E, including Ethernet communications for non-safety monitoring of the inputs (both safety and non-safety) and the safety outputs. The Ethernet communications protocols include: EtherNet/IP, Modbus/TCP and PCCC. Connection to the network is via an RJ45 connector and can use either standard or crossover-style cordsets.Features of the SC22-3E: 32 Configurable Virtual Status Outputs (VO) Track input Track output System lockout status I/O fault System waiting for reset Output waiting for reset Mute status Track input groupConfigured System and Network ParametersFault LogVirtual Status Output Auto Configuration OptionThe SC22-3E Safety Controller uses the new Software/Firmware Version 3.0 which includes the following additions and changes:Adjustable Valve (Device) Monitoring monitors the state of a device controlled by the Safety Output and is adjustable from 100 ms to 5 seconds.Cancel OFF-Delay now allows an OFF-delay to be canceled in two ways: Turn the Safety Output OFF immediately, or allows the Safety Output to remain ON if the Safety Input device is in the RUN state (effectively ignores the stop command)."Cancel OFF-Delay&" Status output indicates when to actuate the “Cancel OFF-Delay” to keep the Safety Output ON"Bypass" Status output indicates when an input is actually "bypassed"Track Input Fault" Status output indicates when an input has faulted"Notes" Document Tab lets the individual annotate details, document revision levels, identify a particular SC22 or machine location, etc. and stores that data on the PC and can be e-mail, printed or exported to .pdf or dxf files. ("Notes" information not

more >>
Walker EMD
$773.00 See It
2891123 - Phoenix Contact-2891123-FL SWITCH SMCS 8GT

FunctionBasic functions: Store-and-forward switch complies with IEEE 802.3 2 priority classes as per IEEE 802.1 P TCP/IP protocol, BootP-capable, port-mirroring, integrated web server function, multicast filtering, IGMP snooping, VLAN, Rapid Spanning Tree (RSTP), PROFINET IO Device, media redundancy protocol (MRP).Management: Web based management, SNMP or over V.24 (RS-232)Redundancy: Spanning Tree 802.1d, Rapid Spanning Tree 802.1w, Fast Ring Detection, Media Redundancy Protocol (MRP) as per IEC 62439Status and diagnostic indicators: Per Ethernet 2 status LEDs: LINK and status activity with switch-over, 100, full duplex, supply voltage Us1 and Us2 (redundant supply voltage) and FAILSupported browsers: Internet Explorer 5.5 or higherGeneral dataAir pressure (operation): 86 kPa ... 108 kPa (2000 m above sea level)Air pressure (storage/transport): 66 kPa ... 108 kPa (3500 m above sea level)Ambient temperature (operation): 0 °C ... 55 °CAmbient temperature (storage/transport): -40 °C ... 85 °CDegree of protection: IP20Depth: 69 mmHeight: 100 mmMounting type: DIN railNoise emission: EN 61000-6-3:2001+A11Permissible humidity (operation): 5 % ... 95 % (no condensation)Permissible humidity (storage/transport): 5 % ... 95 % (no condensation)Type AX: Block-orientedWeight: 650 gWidth: 128 mmInterfacesConnection method: RJ45Connection method: V.24 (RS-232-C), 6-pos. MINI-DIN female connector (PS/2)Interface 1: EthernetInterface 5: Serial (V.24 (RS-232))No. of ports: 8 (RJ45 ports)Note on connection method: Auto negotiation and autocrossingSignal LEDs: Supply voltage, data transmission, error, link, activityTransmission length: 100 m (per segment)Transmission physics: CopperTransmission speed: 10/100/1000 MBit/sNetwork expansion parametersCascading depth: Network, linear, and star structure: anyMaximum conductor length ((twisted pair): 100 mSupply voltageResidual ripple: 3.6 VPP (within the permitted voltage range)Supply voltage: 24 V DCSupply voltage range: 18 V DC ... 32 V DCTypical current consumption: 600 mA (at US = 24 V DC)

more >>
BW Rogers Co
$1,082.52 See It
SC22-3E-C - Banner Engineering Safety Controller with Clamp Terminals, XM Card

New to the Safety Controller family is the SC22-3E, including Ethernet communications for non-safety monitoring of the inputs (both safety and non-safety) and the safety outputs. The Ethernet communications protocols include: EtherNet/IP, Modbus/TCP and PCCC. Connection to the network is via an RJ45 connector and can use either standard or crossover-style cordsets.Features of the SC22-3E: 32 Configurable Virtual Status Outputs (VO) Track input Track output System lockout status I/O fault System waiting for reset Output waiting for reset Mute status Track input groupConfigured System and Network ParametersFault LogVirtual Status Output Auto Configuration OptionThe SC22-3E Safety Controller uses the new Software/Firmware Version 3.0 which includes the following additions and changes:Adjustable Valve (Device) Monitoring monitors the state of a device controlled by the Safety Output and is adjustable from 100 ms to 5 seconds.Cancel OFF-Delay now allows an OFF-delay to be canceled in two ways: Turn the Safety Output OFF immediately, or allows the Safety Output to remain ON if the Safety Input device is in the RUN state (effectively ignores the stop command)."Cancel OFF-Delay&" Status output indicates when to actuate the “Cancel OFF-Delay” to keep the Safety Output ON"Bypass" Status output indicates when an input is actually "bypassed"Track Input Fault" Status output indicates when an input has faulted"Notes" Document Tab lets the individual annotate details, document revision levels, identify a particular SC22 or machine location, etc. and stores that data on the PC and can be e-mail, printed or exported to .pdf or dxf files. ("Notes" information not

more >>
Walker EMD
$861.00 See It
Search within results